EN 1935:2004

Durability shall be classified according to the following grading system:

EN 1303

Durability shall be classified according to the following grading system:

Grade

Cycles

4

25.000

5

50.000

6

100.000

Corrosion resistance shall be classified according to the following grading system:

Grade

Corrosion resistance

Temperature requirement

0

no defined

no

A

high

no

B

no

from -20

o

to +80

o

C

C

high

from -20

o

to +80

o

C

EN STANDARDS’ GRADE CLASSIFICATIONS

Hinge grade

Category of use

Durability

Test door mass

Grade

Duty

Grade

Use

Grade Test cycles Grade Mass kg

2

Light

1

Window

3

10.000

1

20

3

Light

1

Door or Window 4

25.000

1

20

4

Medium 2

Door

7

200.000

1

20

5

Light

1

Window

3

10.000

2

40

6

Light

1

Door or Window 4

25.000

2

40

7

Medium 2

Door

7

200.000

2

40

8

Light

1

Window

3

10.000

3

60

9

Light

1

Door or Window 4

25.000

3

60

10

Medium 2

Door

7

200.000

3

60

11

Heavy

3

Door

7

200.000

4

80

12

Heavy

3

Door

7

200.000

5

100

13

Severe

4

Door

7

200.000

6

120

14

Severe

4

Door

7

200.000

7

160

59